一. Open the doors ways :

After typing the correct password, press the “#” key. At this time, the buzzer will sound twice. The OPEN indicator light will be green on the operation panel , the illumination will be on, and  the light will be off  after 15S (the door will be automatically turned off).

二.  How about revised the user password ?

The user password is 1 to 10 digits, and the factory setting is “1234”.

The method for modifying the user password is as follows:

1. Door opening ,After the green indicator light   off, first press the red button (escape switch) in the upper left corner of the safe door panel. At this time, the yellow indicator of CHG is on, indicating that the password has been changed.

2. In the panel  keypad, type a new  password that does not exceed ten digits, and press the “#” key to confirm.

3. The yellow indicator light is off, the new password is generated, and the old password has been replaced.

三.How about revised the management password

1.The management password is 1 to 10 digits, and the management code is set to “159”

Enter the original management code, press the "*" button, the yellow indicator light is on, enter the new management code, press the "#" button, ring 2 sounds. The yellow indicator light continues to light, enter the same new management code again, press the "#" key, 2 rings, the yellow light is off, and the modification is successful.

2: In the case where there is no escape switch, after opening the door with the management password successfully, enter the original management code in 8S, press the “*” button, the yellow indicator light is on, input the new management code, press “#” button, ring 2 sounds. The yellow indicator light continues to light, input the same new management code again, press the “#” key, 2 sounds, the yellow light is off, and the modification is successful.

四、Vibration sensitivity settings

 When the door is opened, press the escape switch and the orange indicator lights up. Press and hold “*” for 2 seconds. The number of buzzer sounds represents the current vibration level. Press 1-5 to modify the vibration level. The buzzer sounds two. The sound "drip" means that the modification is successful. Example: Press the 1 button to set the vibration level to 1 level. The 5 button represents a vibration level of 5, so the higher the level, the more sensitive the vibration.

五.Alarm function

1. Enter the password incorrectly three times in a row, the alarm sounds for one minute, and enter the correct password to stop the alarm.

2. After closing the door, press the “#” key to start the vibration alarm function, and the buzzer sounds 2 to confirm.

 At this point, use a certain external force to strike or forcibly move the cabinet. The alarm sounds for one minute. Enter the correct password to stop the alarm. When opening the door, enter the correct password, the green light is on, and the vibration alarm function is automatically disabled.

 Remark: When the door opening and closing switch is closed, the above alarm condition will not generate an alarm.

六. Replacement battery

Under  voltage: 4.1V.

After using for a period of time, if the red light flashes 8 times after the door opening operation, the battery is low, please replace the battery inside the built-in battery box.

七."8" key function

         Press it to clear a number you just entered.

Initialization function

Disconnect the power and press the button to put off the remaining energy on the board (or short the two terminals of the DC terminal), then short the two pads of CY1, turn on the power at the same time, the buzzer will sound, and the system will be restored. User password (1234) and factory management password (159), after the initialization is successful, disconnect the CY1 two pads.